PWR-C1-440WDC/2 Overview
Cisco 3850 Series Secondary Power Supply - PWR-C1-440WDC/2, 440W DC Config 1 Secondary Power Supply for 3850 Series.
Quick Specs
Figure 1 shows the appearance of PWR-C1-440WDC/2.
Table 1 shows the Quick Specs.
Product Code |
PWR-C1-440WDC/2 |
Power supply rated maximum |
440W |
Total output BTU (Note: 1000 BTU/hr = 293W) |
1517BTU/hr, 440W |
Input-voltage range and frequency |
-36VDC to -72VDC |
Input current |
<8A at -72VDC <16A at -36VDC |
Output ratings |
-56V at 7.86A |
Output holdup time |
> 2ms at -48VDC |
Power-supply input receptacles |
Terminal strip |
Power cord rating |
20A at 100VDC |
Physical specifications |
(H x W x D): 1.58 X 3.25 X 12.20 in Weight: 2.6 lb |
Compare to Similar Items
Table 3 shows the comparison of PWR-C1-350WAC, PWR-C1-440WDC/2, PWR-C1-1100WAC and PWR-C1-715WAC=.
Product Code |
PWR-C1-440WDC/2 |
|||
Power supply rated maximum |
350W |
440W |
715W |
1100W |
Total output BTU (Note: 1000 BTU/hr = 293W) |
1207BTU/hr, 350W |
1517BTU/hr, 440W |
2465 BTU/hr, 715W |
3793 BTU/hr, 1100W |
Input-voltage range and frequency |
100-240VAC, 50-60 Hz |
-36VDC to -72VDC |
100-240VAC, 50-60 Hz |
115-240VAC, 50-60 Hz |
Input current |
4-2A |
<8A at -72VDC <16A at -36VDC |
10-5A |
12-6A |
Output ratings |
-56V at 6.25A |
-56V at 7.86A |
-56V at 12.8A |
-56V at 19.64A |
Output holdup time |
16.7 ms minimum at 100VAC |
> 2ms at -48VDC |
16.7 ms minimum at 100VAC |
10 ms minimum at 102.5VAC |
Power-supply input receptacles |
IEC 320-C16 (IEC60320-C16) |
Terminal strip |
IEC 320-C16 (IEC60320-C16) |
IEC 320-C16 (IEC60320-C16) |
Power cord rating |
10A |
20A at 100VDC |
13A |
13A |